| 1. True on-line double conversion technology |
2. Highest reliability and maximum performance for power parallel and redundancy N+X |
3. Super wide input voltage range and fully AVR |
4. High input power factor |
| 5. Zero transfer time |
| 6. Controlled by fully digitized DSP+CPU |
| 7. Self diagnosis and protection |
| 8. Protection against all types of power problems |
| 9. Miniaturization design, save on invaluable space |
| 10. No add-on CNTL unit required for parallel connection |
| 11. Low initial investment and flexible for future expansion |
| 12. Advanced IGBT power components, enhancing the overall reliability and conversion efficiency |
| 13. Equipped with Maintenance Bypass Switch achieve online maintenance |
| 14. Smart local and distance monitoring capability with RS232 port, and compatible with SNMP |
| 15. New function design, much more easy to use |
NT- ***** Model-High frequency on-line | TE6K2M/ TC6K2M | TE6K2L/ TC6K2L | TE10K2M/ TC10K2M | TE10K2L/ TC10K2L | TE10K4L/ TC10K4L | TE15K4L/ TC15K4L | TE20K4L/ TC20K4L |
Rated capacity (COSΦ=0.7) | 6KVA | 6KVA | 10KVA | 10KVA | 10KVA | 15KVA | 20KVA |
Input | Input wiring | Single-phase line two + Ground line | Three-phase line four + Ground line |
Voltage range | 176~276VAC | 304~478VAC |
Frequency range | 46~54Hz |
Power factor | 0.97 | 0.95 |
Output | Voltage | 220VAC±2% |
Frequency | Input synchronized the supply frequency (line mode) 50Hz±0.1% (Battery mode) |
Power factor | 0.7 |
Current crest ratio | 3:1 |
Waveform | Sine wave |
Overload capacity | 105%~130% 10min, >130% 1min |
Standard backup time (full or half load) | >7'/20' |
| >5'/13' |
|
Efficiency | >91% | >90% |
Battery Type | (Maintenance-free lead acid battery) |
Voltage of the battery | 240VDC |
Transfer time | Zero interruption |
Automatic Bypass | Integrated |
Indicator | Indicates load/battery capacity, UPS running states etc. |
Audible Alarm | Battery discharge UPS | Sounding every 4 seconds when mains fails |
Sounding every 1 second when battery exbausts |
Abnormal | Beeping continuously |
Parallel Port (option) | Up to three units in parallel for power redundancy and load sharing |
Communication Interface | RS232 + SNMP (option) |
Operating environment | Temperature | 0℃ ~40℃ |
Humidity | 20%~90% |
External/Shipping Size W × D × H (mm) | 260 × 570 × 720 / 350 × 650 × 900 |
Net / Gross weight (kg) | 90/107 | 35/52 | 93/110 | 38/55 | 39/56 | 55/72 | 55/72 |
Option | (SNMP Adapter), Battery cubicle, Parallel Port, Maintenance Switch |
Remark | Specification only for reference. Subject to change without prior notice |
We accept order with special specifications |